Release notes for Warrior Casedhole 120126
|
CH Logging |
Fix for Kuster PL Frames issues in release 110930 |
|
CH Logging |
Updated Hotwell PNN tool processing module and configuration in standard service/tool restore files |
|
Sondex |
CyAux with allowable USB dropout recovery of up to 1 second, reports to Event Log |
|
Memory Logging |
Memory data is converted to the depth domain at the sample rate in the service description, if higher than the default. |
|
All logging |
DSP communication enhanced; especially helpful under Windows 7. |
Release notes for Warrior Casedhole 111116
|
All logging |
Tools using the img.dll module will make the MINAPIWALL variable available, NOMTHK, remains to be calculated from CASEOD and CASEID variables |
|
All logging |
IDOnly sensor bug fix for usr tool module |
Release notes for Warrior Casedhole 111021
|
Memory Logging |
Bugfixes for UniTool support |
Release notes for Warrior Casedhole 110930
|
CH Logging |
Support for Permaworks PTS01 and Spartek (Archer) WLD added |
|
CH Logging |
Telemetry support for Spartek WLD tool, Kuster self-ID frames (PTSC) |
|
All logging |
Migration to latest Cypress device drivers for all SDS USB devices |
|
Memory Logging |
Enhanced support for Probe UniTool |
|
CH Logging |
Caliper Imaging tools casing thickness and remaning wall calculations are now optional, defaulted to off. Tool data has to be centralized for validity |
Release notes for Warrior Casedhole 110722
|
CH Logging |
Image tool module in normal caliper mode producing IDMN and IDMX based on opposing radii, and IDMN2 and IDMX2 based on double radii |
|
All Logging |
Recorder service can now have non integral rates specified for sampling (digitization) down to 2.0 micro seconds |
|
CH Logging |
XIPE caliper tool telemetry minor updates, freeze caused from fast changes to telemetry discriminators fixed |
|
All Logging |
Inclinometer tool module bug fix to correct deviation calculations with 2-axis accelerometer packages |
|
All Logging |
Prestemp bug fix, Gowell type pressure calibration files and calculations |
Release notes for Warrior Casedhole 110418
|
All Logging |
Multiple Power Control dialog bug fixes for new PSAUX board |
|
All Logging |
EDSP serial port communication support bug fix |
|
All Logging |
Support for Probe Telemetry downlink auto-training |
|
CH Logging |
Job Planner option that selects shooting polarity conveyed to shooting panels that can be software monitored and controlled to prohibit incorrect set up |
|
All Logging |
USR tool module sensors can be designated "optional" in such a way that at service load, if not configured, the service will proceed to load |
Release notes for Warrior Casedhole 110223
|
All Logging |
Add '~Other Information' section to LAS file. Can be used for comments longer than 255 characters. Add [Other] section to LAS.ini, and below that enter the name(s) of the heading entry that you want in the ~Other section: [Other] 1=COMMENT, etc. |
|
CH Logging |
Logging System providing shooting panel voltage and current calibration defaults in absence of actual performed calibrations |
|
All Logging |
Caliper Motor current calibration defaults provided per panel type in absence of actual performed calibrations, realtime caliper current output added |
|
All Logging |
Automatic support for the PSAUX board updated to include save/retrieve of TVOLT and TCURR calibrations |
|
All Logging |
Multipulse DSP scripts now have capability to specify period measurements on individual channels |
|
All Logging |
Event Log reporting of Calibration Edits |
|
CH Logging |
Master calibration for Probe Multi-Finger Caliper bug fix |
Release notes for Warrior Casedhole 101214
|
All Logging |
New logging service control PowerSafeDepthFt added. Used to inhibit software controlled tool power until a specified depth is reached. |
Release notes for Warrior Casedhole 101210
|
CH Logging |
Spartek XY Caliper support added |
|
CH Logging |
Kuster PTS-CCL telemetry support (Version 3) |
|
CH Logging |
Robertson CBL telemetry bug fix, more precision (10uS) on downlink pulse widths |
|
All Logging |
Updates to cater to problematic time stamped data packets from the ASEP Smart Monitor |
Release notes for Warrior Casedhole 100816
|
All logging |
Added export step size 0.0025 for 400 smp/m |
|
CH Logging |
Spartek telemetry using paced downlink when available |
|
All logging |
LTEN sensor selection (LTEN or LLMTEN) stored in db for recalc purposes |
|
All logging |
Gradio module, density from single pressure sensor calculation option |
|
CH Logging |
Enhaced MUXB support for CQPT |
Release notes for Warrior Casedhole 100715
|
All |
AuxPS device supporting HVAC control via tool power dialog or configured on/off |
|
All |
MUXB version 2 telemetry support - QP/QT channels |
|
All Logging |
New option for individual services to define a minimum time before tool power can be reenabled after switching off. |
|
All Logging |
Support for Kuster SRO through comm port |
|
All Logging |
Hole volume related outputs correctly follow the user's preferred units as selected in the control panel. |
|
PittsAN service |
Bugfix data garble preventing re-sync after a sync loss |
|
CH Logging |
Tracer Eject using CTRL-F8 for eject hotkey |
|
All Logging |
Support Kuster tools through panel |
|
All Logging |
Inclinometer filtering sensors, not outputs |
|
All Logging |
Support for AKS telemetry through serial port |
|
CH Logging |
CFB Flow tool module option for single signed sensor type |
|
All Logging |
Gauge can show more decimal places |
|
All logging |
PRESTEMP support for Gowell Quartz gauge |
|
All logging |
Relay Control lock up issue fixed |
|
CH Logging |
New Drawing Reference option - can use casingID/OD variables or can use borehole ID variable +/- an offset entered in the options dialog. |
|
All logging |
MW Acoustic Scanner support |
|
All logging |
Warrior Import Program, fix for filter delay |
|
All logging |
Optional unfiltered GR output additional to filtered |
|
All logging |
Add option for jpeg files - draw image to scale |
|
All logging |
AddTVD - warn if current depth entry < previous. VSDir part of Tie-On window. 3D view - Changed default orientation -> North on top. Enhance 3d closure so background and scales stay in the 'back' as you rotate. InitTVDCalc check for zero points. |
|
All logging |
Scales for correlation curves have run/pass name included.. Speed up Iplot when plotting correlation curves. |
|
All logging |
The right click window can show correlation values also. |
|
All logging |
When editing a curve, can right click in the log insert to select a curve as well as right clicking on the curve itself. |
|
All logging |
Modified import program to support USB DAT drive - see DAT Drives ReadMe.txt in Manual folder for details. |
|
All logging |
New export program to support USB DAT drive - see DAT Drives ReadMe.txt in Manual folder for details. |
|
CH Logging |
Fixed CWH tool multi-point type functionality |
|
All logging |
Probe telemetry scriptable downlink baud rates |
|
CH Logging |
MUXB version 2 telemetry dual spinner support |
|
CH Logging |
Flexstak downlink slider gain control (optional) added |
|
All logging |
Report Power Monitor warnings in Event Log |
|
All logging |
Allow long serial id's for PRESTEMP tool software in the Tool Editor |
|
All logging |
PRESTEMP Tool Module will import external calibration files when previously imported cals had no date associated with them |
|
All logging |
ASEP smart Monitor memory leak fixed - update provided by ASEP |
|
All logging |
ASCTEL support of generic float(s) channel, "IFS" designation |
|
All logging |
Probe PTX handling ratio channel types and backward compatibe to script specified time-base counter channels |
|
CH Logging |
IMG module now uses linear interpolation. Bad arms marked with 'X" in tool monitor window. |
|
All logging |
OBDC interface can now import into existing database/dataset. |
Release notes for Warrior Casedhole 090618
|
All logging |
Option for 5 and 6 decade log plots. Option for bold decades on logarithmic plots. |
|
All logging |
Both hole volume values and ticks are now generated as per Sondex request. |
|
CH Logging |
Support for Alphaneutronics telemetry |
|
All logging |
Fix for the standard Printrex 820 ( non DL ) printer |
|
All logging |
Log format editor - Invert insert display to match log plot. |
|
All logging |
Surface and TD alarms were not working when speed was positive for logging up. |
|
All logging |
For TVD correction, check if any inputs have depth correction selected. Prompt user if necessary. |
|
All logging |
HEXION DSGR Tool module added |
|
All logging |
Fix preview of cal report from Acqusition window |
|
All Logging |
Alpha Neutronics telemetry based compensated neutron support added |
|
All Logging |
Use -999.25 for undefined and infinite numbers. Use -999.25 for unpacked numbers > 11 digits. |
|
All Logging |
Can load annotations from another log pass with annotation editor |
|
CH Logging |
PIP panel Turbine and Surface Pressure support |
|
All Logging |
Inclinometer Min/Max calibration option |
|
All |
Enhanced Event Logging |
|
All |
Inclinometer time to depth mode compatible |
|
CH Logging |
SCBL optional pseudo 3ft amp from sector calc |
Release notes for Warrior Casedhole 081212
|
TVD Calculations |
Min curvature is now the default formula. Old formula requires warrior.ini setting in [TVD] section: "Formula=Original" - Min curvature formula does not require warrior.ini setting |
|
All Logging |
Added CSS Slim CF252 Compensated Neutron Tool |
|
All Logging |
Corrected Ellipse area calculation formula, which is used for BH-Vol using XY Calipers |
|
All Logging |
Support for Robertson Geologging FWS and CBL tools with STIP |
|
All Logging |
Line Termination default set to High |
|
All Logging |
Added ability to opt for "comma-separated" values. |
|
All Logging |
Updated CNTP Titan algorithms |
|
All Logging |
Fix for extra long and multi page tiff files that are used for plot job input. |
|
CH Logging |
Tracer program crash at Recording stop bug fixed. |
|
All Logging |
Added user performable calibration sequence. |
|
All Logging |
Fix bug for calibration terms and support Lin1pt calibration with one sample point appropriatly |
|
All Logging |
ALT and DETEQ telemetry support directly from AUX channel with pulse discrimination |
|
CH Logging |
Enhancements for drawing highlight areas while perforating |
|
All Logging |
Add support for Printrex843, Sending less data to Printrex printers - using compression |
|
CH Logging |
Keep viewer in sync with interactive plot |
|
All Logging |
Bug fix depth on Y axis |
|
CH Logging |
Can disable items in XY plot, so this can be used as a quality indicator. Show data points without showing calculations |
|
CH Logging |
Break pip tally annotations into two lines |
|
All Logging |
Enhance long/multi page tiff files |
|
All Logging |
Bug fix tape handling |
|
All Logging |
Bug fix tape handling |
|
All Logging |
Make units translation more accurate. Bug fix tool import |
|
CH Logging |
More enhancements for perf job planner |
|
All logging |
Sondex/CSS CNTP CF252 calibration fixes |
|
TCP |
Fix for TCP drawing with broke tool lengths. |
|
All logging |
Window was preventing hardcopy dialog from being displayed |
|
All logging |
Fix error message from interactive plot at log stop when in Preview mode |
|
All logging |
New Titan Sand, Lime and Dolomite calculations. |
|
All logging |
New Titan Neutron Algorithm. |
|
All logging |
Fix multiple pass automerge for time based logs |
|
All logging |
New Titan Neutron Algorithm; refinement over change done on Aug/25/2008. |
|
All logging |
Annotation edit dialog is resizeable. Use File->Save Window Position option to save for next time. |
|
All logging |
Project measured depth given a TVD. Can add a tie-on survey point with TVD, North, East, and then enter TVD survey points from there. |
|
CH Logging |
Added user mnemonics to CWH tool module |
|
All logging |
Noise sound files should now play back in Windows VISTA. |
|
All logging |
Corrected sound file normalization, and correct gain value in dB. |
|
All logging |
Wavefile export dialog shows station number instead of ordinal number. |
|
CH Logging |
Support Panex 2nd PQ DSRO |
|
CH Logging |
Enhancements to log Gradio based on dual pressure outputs |
|
CH Logging |
Pipe tally annotations were missing top joint, and pipe tally report was missing bottom joint |
|
All logging |
Shooting impedence and differential impedence calculated from available outputs |
Release notes for Warrior Casedhole 071220
|
All Logging |
Fixed bug that kept some logs from starting |
Release notes for Warrior Casedhole 071207
|
All logging |
SGR frame time corrections and storage of cals in tools.ini |
|
All logging |
Robertson SCNT slim-hole neutron model added. |
|
All Logging |
SDS CY driver updates to disconnect/reconnect gracefully |
|
All Logging |
LASW - Added default step size option to main dialog. If you enter 0.5 for the default, then the next time the program starts, the Current sample rate will be set to 0.5 |
|
All Logging |
LASW - Handle longer time logs |
|
CH Logging |
Multiarm.exe works better with new BHImg.dll. Added bhimg presentation option to main dialog. Must select a bhimg presentation for 3D Viewer to start. |
|
All Logging |
After total restore, run reinstall of drivers after reboot. |
Release notes for Warrior Casedhole 070814
|
Depth |
In depth control, separate button added to connect to Depth Panel. Apply button will only apply depth. |
|
CH Logging |
Hotwell PNN detection enhancements with auto thresholds |
|
CH Logging |
HDB3 (XIPE Caliper) and DAQING (Probe Caliper) telemetry enhancements |
|
All logging |
Fixed IMG PERR, MINR and MAXR curves |
|
CH Logging |
Sector based BIx and Attenuation curves, as well as an Image map. |
|
All logging |
External Power Supply Support |
|
All logging |
New CCL board support |
|
All logging |
CPFD and CPFH added |
Release notes for Warrior Casedhole 070628
|
All logging |
User defined depth units reflected in naming of exported noise station wave files |
|
CH Logging |
Additional tool support for Spartek ILS and NFL |
|
OH Logging |
SP procesing optional through this tool module. |
|
All logging |
CanadaTech Pres. Support. |
|
All logging |
Added optional realt time output to usr tool module sensors |
|
TVD Calculations |
Add Minimum Curvature calculations. Requires warrior.ini setting in [TVD] section: "Formula=MinCurvature" |
Release notes for Warrior Casedhole 070511
|
All Logging |
Support for Open Hole Shooting panel type |
|
All logging |
Add UTCTIM, LOCTIM outputs. Add to service same as TOD -> "LOCTIM=AUX,ELTIM". LOCTIM is local time in seconds since 1/1/1970. UTCTIM is seconds referenced to GMT. |
|
Printing |
Can print long jpegs. |
|
Plotting |
Add option to create black grid lines for a particular printer - overrides whatever grid lines were set to in log format. Some windows printers look better with black vs gray grid lines. |
|
Plotting |
Multi line log inserts. Signature spectrums can have colors. More control over grid lines. |
|
Plotting |
Multi line log inserts. Signature spectrums can have colors. |
|
Plotting |
Users have more control over how grid lines are created. |
|
TVD plotting |
New 3D closure plot. |
|
Control Panel |
Show version info in Control Panel. |
Release notes for Warrior Casedhole 070322
|
All Logging |
Daqing Caliper support, filter support for meas sensor |
|
PIP Logging |
Support FX1 based Pip panels |
|
All Logging |
Support Probe Shooting Panels with no AC shooting power capability |
|
All Logging |
Probe 2.75" CNT tool dolomite response updated |
|
All Logging |
Added option to show/hide offsets of non-serial items |
|
All Logging |
Fixed Wargauge alarm settings not all translated to/from metric properly |
|
LAS Export |
Added option to output variables as LAS curves |
|
All Logging |
Lis2War uses standard Geodetic Units functions. |
|
All Logging |
Fixed Usr Tool calibration date bug. |
Release notes for Warrior Casedhole 061031
|
Plotting |
Added filter report. Fix plot jobs with multiple bitmaps. More accurate plotter calibrations. |
|
All Logging |
Optional Verifications for usr.dll tool software |
|
All Logging |
XIPE multi-arm caliper support |
|
PL Logging |
Made outputs available for time to depth logs |
|
SDSTIP |
Support solid-state aux power switching ("RelayPowerGate") |
|
Noise Logging |
Manual gain (range setting) option for noise service |
|
TVD Calculations |
Can read in curves from log pass for input to tvd calculations |
|
PIP |
PIP panel PPAB Speaker output support |
Release notes for Warrior Casedhole 060825
|
Log formats |
Add Image 3D and Potato plot types for multi arm caliper array data. |
|
Plotting |
Can start XYPlot when service starts like Iplot. Extra parameters entered in Services Editor. |
|
All logging |
Generic Borehole Imaging tool module |
|
All |
Bugfix recalculation of depth-shifted data |
|
CH Logging |
Titan telemetry 24 bit raw data channel support |
|
All Logging |
Temp. Compensated XY Caliper tool; ported to Win-32. |
|
Printing |
Add calibration for Windows printers |
|
CH Logging |
Added spinner calculation program - Flowvelocity |
|
All logging |
Compatibility fix for FX1 based hardware with VIA USB host controller |
|
All logging |
Average Caliper output added to XYCal; slight clean-up. |
|
Perforating |
Use service dump for more accurate sensor offset calculations. Bug fix - Closing all from Acquisition while wizard was open could delete joplan entries. |
|
Tool string drawing |
Use service dump for more accurate sensor offset calculations. |
|
Alarms |
Alarms now can be canceled in groups - depth, depthpnl using new alarms. |
|
All logging |
Multiple gain/filter board support, new I2C system addressing enhancements |
|
All logging |
Multiple DSP board support |
|
All logging |
New I2C system addressing enhancements, support for USB44R6 |
|
All logging |
New I2C system addressing enhancements |
|
TVD Calculations |
Uses new tvd library - DS points will be saved in a database instead of external file. TVD plots won't need to be saved to database, can be added to plot job later. |
|
All logging |
CNTP-313-B Probe Tool Added - New Algorithm. |
|
Headings |
Headings can have watermarks |
|
CH Logging |
Panex Spinner Flow support |
|
Tool string drawing |
User can create their own list of sensors to hide in the tool string drawing. File logsys.ini, section [ToolDiagramSkipSensors], then list sensor names 1=SENS1, 2=SENS2, etc. |
|
Plotting |
Can enter a decimal value for line thickness to fine tune curve thickness on printers with resolution >= 300 |
|
Well Objects |
Casing, plugs, packers can have colors. |
|
All logging |
New device for surface acquisition |
|
All Logging |
Bug fix for data transfer |
|
Tool Power Monitor |
Bugfix tool power monitor config, inhibit. Can now declare “NoMonitor=yes” in specific services (or globally via Warrior.ini) |
Release notes for Warrior Casedhole 060407
|
CH Logging |
Hotwell PNN downlink timing improvement and biased output returns to max. pos. rail for larger neg. deflections |
|
All logging |
Nominal gains and offsets for Tvolt and Tcurr by panel type |
|
CH Logging |
Sondex PL telemetry has new channel type "flowdir2" for modified XMW using two channels for flow rate and direction |
|
CH Logging |
Fix for PIP panel PLL multipliers |
Release notes for Warrior Casedhole 060321
|
All logging |
Bug fix - Could cause "Unable to create curve" errors at log up time. |
|
Windows printing |
Can adjust resolution of Windows Printing source data via Warrior Control Panel. Lower resolution speeds up printing but can lower print quality. This setting is used in addition to the printer resolution set in the Windows printer settings. |
|
XY Plot |
Legend for curve names, Editable legend items, Uses banner for heading, Can plot constant values for reference. |
|
Plotting |
Add entry to warrior.ini in [Heading] section for "defaultbanner". If entry not there then will use title.wlb |
|
Sondex Support |
Sondex PL supports flow detection on all lines including H2S. QPS bug fix |
|
Plotting |
Can show legend for shading in log inserts |
|
All Logging |
Prohibit Panel Type change (flag setting to enable in Warrior.ini) |
|
All Logging |
Logging releases use new style device drivers |
|
All Logging |
Sondex name fix, gauge overflow fix, smoother output filename handling |
|
All Logging |
Fix resource leak - was causing misc. device record and storage errors when recording multiple passes of logs with many outputs |
|
Perforating |
New Perf Job Planner |
|
Panex Support |
Panex GR support, other updates per Panex |
|
Cal reports |
Cal reports now have a heading with database and dataset source for cals. |
|
Printrex printing |
For 820RM printers, add 820RM=1 to printrex printer section in warrior.ini. |
|
Heading |
Added 'U' for underline edit type in .hdg file. "editHSLTU", "editVSLTU", etc. |
|
Services Editor |
Tools will be exported with service into wcf file by same name as wsv file. Tools can be imported with service by same method. When editing tools for service, can see list of current tool/serial numbers to pick from. |
|
Panex Support |
Bug fix to coefficients file read in |
|
Panex Support |
Enhanced Panex monitor and control |
|
Creating Alias |
Dialog will not close after alias created, but user will see status message if alias created successfully. |
|
Backup |
Was not checking set aside space for backups properly. |
|
LIS export |
Added option "OneFramePerRecord" to [LIS Export] section. Required for WellCad software to read sonic data. |
|
Cal reports |
Can draw rectangles around entries by prepending underscore before text. [Columns] entry can have start,stop values ( 1=0,20 ), and stop value for columns is required for rectangles to come out correct. |
|
SCBL |
Can manually adjust gates after automatic moves |
|
Waveform Display |
When multiple waveforms are in window, double click to fill window with that waveform and double click again to go back to multiple display. |
|
Plotting to Fax |
Move plot options to config dialog like other printers. Add option for Normal ( 100dpi ) and Fine ( 200dpi ). Default is Fine - which is what it was hard coded to before. Requires new entry in warrior.ini for [Fax] - "custom=faxfile32.dll". |
|
Well Objects |
Well object Highlight type can have different colors. Perfs with single depth will show up now. |
|
Plotting |
Added 'repeat' mode for correlation curves. Correlation curves will only be plotted if that curve is shown. So you can show curves from main pass on top of repeat pass to easily see repeatability |
|
All Logging |
Default software power controls to be off, override via new control word in service or global enable via warrior.ini |
|
All Logging |
New safety feature: Tool Power will be disabled if line current drops out |
|
Merge |
Warn user if depth correction is entered and no curves have depth correction to be applied |
|
Tracer Interp |
Can use caliper reading as casing ID value for calculations |
|
CH |
Support for Geofizika PL string |
|
Tool string drawing |
Was not always showing proper offsets for tracer tools |
|
All Logging |
Open line monitor temporarily inhibited during tool power voltage/current calibration |
|
Perforating |
Update CYShpl support to monitor AC/DC and Pos/Neg switch positions when available |
|
All logging |
Modifactions to Sondex/CSS Compensated Neutron calibration and verification routines |
|
Config restore |
Run latest warrior convert option when restoring config files |
|
Tool string drawing |
Fix for multiple instances of the same tool |
|
Direct printing |
First plot from Job Editor will be spooled so printer won't start/stop |
|
LAS Export |
Fix CNTY=COUNTY |
|
XY Plot |
Can turn off curve labels. Added more curve styles. Print directly to Windows printer for better quality. |
|
Hot var editor |
Was not working properly on numeric values. |
|
Waveform plotting |
Fix for low vdl levels - before were coming out all white. |
|
Interactive plot |
Bug fix hangup of Iplot if you have it minimized and save a well object to the same database. |
|
All logging |
Big fix for probe telemetry channel offset and Titan "combined" channel types |
|
Services,Tools editor |
Saving a service will also create a file with tools for that service, then Import will look for both files |
|
Format editor |
Speed up reading/writing of log formats |
|
All logging |
CYAuxF1 - new device support |
|
DSP logging |
Ability to specify pmon for "Probe" command |
|
All logging |
Tool Power monitor settings can be specified per service |
|
All logging |
Robertson Geologging 6 Channel and 12 Channel Telemetry support |
|
All logging |
CYShPnlF1 - new device support |
|
CH Logging |
Includes Hotwell PNN |
Release notes for Warrior Casedhole 051110
|
LAS Export |
User can add their own heading information via [Heading] section in las.ini |
|
All logging |
Bug fix - Could cause "Unable to create curve" errors at log up time. |
|
Windows printing |
Can adjust resolution of Windows Printing source data via Warrior Control Panel. Lower resolution speeds up printing but can lower print quality. This setting is used in addition to the printer resolution set in the Windows printer settings. |
|
All logging |
Legend for curve names, Editable legend items, Uses banner for heading, Can plot constant values for reference. |
|
Plotting |
Add entry to warrior.ini in [Heading] section for "defaultbanner". If entry not there then will use title.wlb |
|
Sondex Support |
Sondex PL supports flow detection on all lines including H2S. QPS bug fix |
|
Plotting |
Can show legend for shading in log inserts |
|
All Logging |
Prohibit Panel Type change (flag setting to enable in Warrior.ini) |
|
All Logging |
Logging releases use new style device drivers |
|
All Logging |
Sondex name fix, gauge overflow fix, smoother output filename handling |
|
All Logging |
Fix resource leak - was causing misc. device record and storage errors when recording multiple passes of logs with many outputs |
|
Perforating |
New Perf Job Planner |
|
CTS Telemetry |
CTS Telemetry monitor showing Caliper commands |
|
Sondex Support |
Sondex MIT supported |
|
Panex Support |
Panex GR support, other updates per Panex |
|
Cal reports |
Cal reports now have a heading with database and dataset source for cals. |
|
Printrex printing |
For 820RM printers, add 820RM=1 to printrex printer section in warrior.ini. |
|
Heading |
Added 'U' for underline edit type in .hdg file. "editHSLTU", "editVSLTU", etc. |
|
Services Editor |
Tools will be exported with service into wcf file by same name as wsv file. Tools can be imported with service by same method. When editing tools for service, can see list of current tool/serial numbers to pick from. |
|
Panex Support |
Bug fix to coefficients file read in |
|
Panex Support |
Enhanced Panex monitor and control |
|
Creating Alias |
Dialog will not close after alias created, but user will see status message if alias created successfully. |
|
Backup |
Was not checking set aside space for backups properly. |
|
LIS export |
Added option "OneFramePerRecord" to [LIS Export] section. Required for WellCad software to read sonic data. |
|
Cal reports |
Can draw rectangles around entries by prepending underscore before text. [Columns] entry can have start,stop values ( 1=0,20 ), and stop value for columns is required for rectangles to come out correct. |
|
Memory Logging |
Major enhancements for LGAT, Lonkar Gamma Analysis Tool |
|
SCBL |
Can manually adjust gates after automatic moves |
|
Waveform Display |
When multiple waveforms are in window, double click to fill window with that waveform and double click again to go back to multiple display. |
|
Plotting to Fax |
Move plot options to config dialog like other printers. Add option for Normal ( 100dpi ) and Fine ( 200dpi ). Default is Fine - which is what it was hard coded to before. Requires new entry in warrior.ini for [Fax] - "custom=faxfile32.dll". |
|
Well Objects |
Well object Highlight type can have different colors. Perfs with single depth will show up now. |
|
Plotting |
Added 'repeat' mode for correlation curves. Correlation curves will only be plotted if that curve is shown. So you can show curves from main pass on top of repeat pass to easily see repeatability |
|
All Logging |
Default software power controls to be off, override via new control word in service or global enable via warrior.ini |
|
All Logging |
New safety feature: Tool Power will be disabled if line current drops out |
|
Merge |
Warn user if depth correction is entered and no curves have depth correction to be applied |
|
Tracer Interp |
Can use caliper reading as casing ID value for calculations |
|
CH |
Support for Geofizika PL string |
|
Tool string drawing |
Was not always showing proper offsets for tracer tools |
|
All Logging |
Open line monitor temporarily inhibited during tool power voltage/current calibration |